Twin towers performed well

Structural engineers were amazed that the World Trade Center towers managed to stay up for so long, reports Steve Turner.

Performance of the structures American Society of Civil Engineers manager for technical activities James Rossberg insisted that the assault on the World Trade Center towers was way above what could be considered a design condition.

'They performed extremely well and were a tremendous testament to the engineers that built them.'

It is believed that the aircraft took out a substantial number of columns and floors in the impact.

This left columns unpropped and spanning beyond design capabilities.

Heather Stanley, managing director of consultant Yolles Partnership, said that the tube design of the towers - in which the outer skin of the building resisted most torsion forces - would have been very effective at resisting the initial impact. The design had redundancy and the structure's multiple load paths allowed holes from missing columns to be bridged.

Engineers suspect that the initial impact would also have disrupted the fire protection on much of the steelwork leaving it exposed to enormous temperatures as the aviation fuel exploded.

Resistance to fire Ysrael Seinuk, president of skyscraper design specialist Cantor Seinuk, confirmed that the unexpectedly high temperatures effectively 'cooked' the towers. He added that the relatively narrow windows would not have allowed heat to escape, compared to more modern glazing that would have blown out.

Only the offshore industry invests in fire protection to prevent collapse at such high temperatures, Professor Dougal Drysdale of the University of Edinburgh explained. Critical members on many oil and gas platforms have cladding to insulate steel up to 1,000infinityC, plus extensive water drenching systems.

Collapse resistance Once the exterior columns and central steel core were weakened by the heat, the weight of the floors above caused them to buckle and collapse. The force from the floor above induced a progressive collapse.

But Heather Stanley dismissed the idea that this collapse could have been designed out. 'The load on the members would have been astronomical, ' she said. 'What would be reasonable provision? Ten storeys? Fifty storeys?'

Have your say

You must sign in to make a comment

Please remember that the submission of any material is governed by our Terms and Conditions and by submitting material you confirm your agreement to these Terms and Conditions. Please note comments made online may also be published in the print edition of New Civil Engineer. Links may be included in your comments but HTML is not permitted.