Levee design failures worsened Katrina floods

News

POORLY DESIGNED and constructed levees aggravated fl ooding in New Orleans after Hurricane Katrina, senior United States engineers have said.

Levees failed in some places without being overtopped or exposed to a storm surge greater than that for which they were designed.

Shallow sheet piles, bad ground conditions and inconsistent use of construction materials all contributed to the failure of the city's flood protection system, the engineers said.

hese conclusions were published in a report by the American Society for Civil Engineers (ASCE) and University of California Berkeley.

'In Lake Pontchartrain the levels of the actual winds were much less than a Category 4 storm and may have been as low as Category 2 or 1, ' said ASCE team leader Peter Nicholson.

The report says levee breaks in this area of the city were caused by 'massive underseepage' passing beneath 'relatively short sheet piles', and through foundation soils, which were a mix of sand, marsh and peat.

This removed support for the flood walls, which then gave way to the force of the storm surge.

Where flood walls were overtopped the report found that the levees' resistance was undermined by transitions between concrete, steel and earth levees, sometimes within 15m to 30m.

Weak points in the levees were often caused at transition points between concrete, sheet piled and earth constructions.

Have your say

You must sign in to make a comment

Please remember that the submission of any material is governed by our Terms and Conditions and by submitting material you confirm your agreement to these Terms and Conditions. Please note comments made online may also be published in the print edition of New Civil Engineer. Links may be included in your comments but HTML is not permitted.